Paul Yaw wrote:
Hi everybody,
Here is the spreadsheet output from the turbo 13B with the proper
correction to STP
PRINT # 187 A1417.WC 13BT.CFG No Fric. Fact May 4 '99 10:56
PM Pg 1
Yaw Power Products 520-670-0110
DEPAC # 99 Thu Apr 29 '99 6:10 PM F1200 Flow Tst# 1417 2200 to
6600 RPM
ROTARY13.CFG IF: 10 29.23" Dry Air @ 25C FUEL SG .755 Time
35.9
Disp:80
RPM HP TorQ Fuel A/F BSFC CFM V Eff CFM/HP TIME
BAND STP STP #/Hr RATIO #/HrHP % SEC
2205 54.0 128.4 24 15.05 0.475 84 82.6 1.558 3.0
2300 56.6 129.3 27 14.08 0.503 88 82.4 1.546 2.6
2400 59.5 130.2 31 12.92 0.547 92 82.8 1.542 1.3
2500 61.8 129.8 34 12.30 0.581 96 83.4 1.559 1.2
2600 64.6 130.5 37 12.01 0.599 101 84.4 1.569 1.4
2700 68.3 132.9 39 11.53 0.611 105 84.2 1.537 0.7
2800 71.9 134.9 41 11.70 0.599 110 85.1 1.530 0.9
2900 75.3 136.4 41 12.04 0.580 115 85.7 1.524 0.8
3000 79.0 138.3 43 11.89 0.578 119 85.6 1.501 0.6
3100 80.5 136.4 45 11.72 0.593 122 85.2 1.516 1.2
3200 83.1 136.4 46 11.68 0.591 125 84.7 1.506 0.9
3300 86.1 137.1 47 11.78 0.583 129 84.6 1.497 0.9
3400 89.3 137.9 49 11.75 0.584 134 85.2 1.498 0.9
3500 93.3 140.1 51 11.73 0.581 139 85.8 1.486 0.9
3600 97.2 141.9 53 11.73 0.582 145 87.1 1.490 0.7
3700 102.3 145.2 57 11.72 0.585 153 89.6 1.497 1.6
3800 108.6 150.1 60 11.65 0.583 161 91.7 1.482 0.9
3900 113.6 153.1 64 11.53 0.594 170 94.3 1.494 0.6
4000 120.2 157.9 68 11.40 0.600 179 97.1 1.492 0.6
4100 133.2 170.6 75 11.52 0.599 200 105.9 1.505 3.1
4200 141.4 176.8 80 11.40 0.60 211 108.5 1.489 0.4
4300 147.4 180.0 83 11.43 0.59 219 110.1 1.483 0.4
4400 155.1 185.1 85 11.59 0.58 228 112.0 1.468 0.3
4500 160.7 187.6 88 11.57 0.58 235 113.3 1.464 0.4
4600 166.6 190.2 91 11.68 0.58 245 115.3 1.471 0.3
4700 172.2 192.5 94 11.72 0.58 254 117.1 1.475 0.4
4800 177.9 194.6 98 11.65 0.58 264 118.9 1.482 0.4
4900 184.0 197.2 100 11.80 0.576 273 120.5 1.482 0.6
5000 187.8 197.2 102 11.89 0.577 281 121.7 1.497 0.7
5100 193.2 198.9 105 11.95 0.576 290 123.1 1.501 0.6
5200 197.2 199.2 109 11.77 0.584 296 123.1 1.499 0.6
5300 201.2 199.4 111 11.82 0.585 303 123.9 1.507 0.7
5400 204.7 199.2 113 11.90 0.585 311 124.8 1.520 0.9
5500 210.2 200.7 116 11.85 0.583 317 124.8 1.508 0.5
5600 215.4 202.0 118 11.82 0.58 323 125.0 1.501 0.4
5700 219.3 202.1 123 11.65 0.595 331 125.9 1.511 0.5
5800 224.1 203.0 127 11.60 0.60 340 127.1 1.519 0.3
5900 230.6 205.3 130 11.69 0.60 350 128.5 1.518 0.4
6000 235.9 206.4 132 11.73 0.59 358 129.3 1.519 0.3
6100 240.0 206.6 137 11.68 0.60 369 131.0 1.538 0.2
6200 247.9 210.0 140 11.74 0.60 380 132.6 1.532 0.3
6300 252.0 210.1 144 11.73 0.60 389 133.7 1.543 0.3
6400 256.4 210.4 146 11.78 0.603 398 134.5 1.550 0.5
6500 262.2 211.9 151 11.66 0.61 405 135.0 1.546 0.4
6568 263.7 210.9 153 11.59 0.62 410 135.3 1.556 0.3
PY
Great stuff Paul. The BSFC shown is full load of course. At 75% power
say
at 4000-5000 RPM the owner could of course lean it and get better
BSFC. Particularly at altitude. The full power BSFC is not that far
off a turbo Lycoming or Continental aircraft engine best power BSFC.
Thanks for the great data Paul. One question. I assume the time
shown is the length of time the engine generated that amount of
power. If that is indeed the case can your flow meter respond that fast?
What kind of TIT's or EGT's are we looking at?
Paul Lamar
The Aircraft Rotary Engine Newsletter. Powered by Linux.
http://home.earthlink.net/~rotaryeng/ http://www.linux.org