Subject: Affect of loss of lubrication and cooling on the apex seals.
From: Paul
Date: 5/9/1999, 11:50 AM
To: zz

Since Jon has brought this subject up and 
rotor housing cooling has not been mentioned on the new letter
for quite some time so perhaps it is time we went over this
again.

This is the temp distribution in the rotor housing.
Here too the bi-metalic affect can warp the housing at high power and
lose sealing efficiency. Jim Mederer at RB has addressed this issue
by grinding groves inside the water jacket to increase the heat transfer
to the cooling fluid and decrease the tendency of the inner wall
to warp at high temps. I would consider this essential for any high 
powered rotary engine. Most of us using rotary engines in 
aircraft have taken this modification for granted. 

I would also use ceramic seals for the same reasons.

I am quite sure Mazda is aware of the issue and has changed the detail
design of the rotor housing over the years.