Paul Yaw wrote:
Paul wrote:
Since Jon has brought this subject up and
rotor housing cooling has not been mentioned on the new letter
for quite some time so perhaps it is time we went over this
again.
This is the temp distribution in the rotor housing.
Here too the bi-metalic affect can warp the housing at high power and
lose sealing efficiency. Jim Mederer at RB has addressed this issue
by grinding groves inside the water jacket to increase the heat transfer
to the cooling fluid and decrease the tendency of the inner wall
to warp at high temps. I would consider this essential for any high
powered rotary engine. Most of us using rotary engines in
aircraft have taken this modification for granted.
I would also use ceramic seals for the same reasons.
I am quite sure Mazda is aware of the issue and has changed the detail
design of the rotor housing over the years.
tempdist.jpg
Paul
This power loss is most likely caused by the apex seals expanding to the
point that they no longer move freely in the groove. This can be a real
problem with the multi piece cast iron seals because they typically get
installed "As is" which is a pretty tight fit in the groove. The
ceramic seals with their lower expansion rate can be fit tighter than
the cast iron or carbon seals.
This is just one more argument for using the ceramic seals in AC
applications. The engine that I ran with no apex oil did have the water
jackets modified, and that may be partially responsible for the lack of
problems. The closest that I had to a sustained power situation was
towing the racecar to Phoenix. During that time, I had the in car dyno
installed, and if I remember correctly I was running at about 75
horsepower. Much less than would be needed in a plane or marine
application.
PY