Subject: Ball check valve in e shaft for rotor squirters.
From: Paul
Date: 5/10/1999, 6:44 AM
To: zz

JMLBlues@aol.com wrote:

We have not found the check balls to be an issue in marine applications. The
biggest (only) failure mode we have seen on marine engines is overheat due to
loss of cooling water flow. A previous company with a similar product had
some failures on supercharged engines due to a combination of overadvanced
timing, insufficient oil metering, and boost a little too high for the
timing/oil. Failure mode was apex seal breakage.

That is what the guys in drag racing found out with their alcohol/
nitrous oxide burning 730 HP 13B two rotors. If you mess up the
timing or anything else and the engine detonates
the apex seals break. They are all now running ceramic 3 mm apex seals.
Last time I talked to Able Ibbarra he mentioned getting 
some custom 2.5 mm wide ceramic seals to up the RPM beyond 10,000! :-)
BTW they all run knock sensors with custom knock sensing electronics.


Regarding enlarging the rotor oil cooling jet orifices -- I have no firsthand
experience on Mazda engines, but on other experimental rotaries we found that
there is an optimum range for the size of the jet. Too little oil undercools
for obvious reasons. But too much oil flow was theorized to result in too
much oil remaining in the cooling cavities. The oil that cools the rotor is
ejected towards the oil drain scupper by the eccentric motion of the rotor.
It is desired that most of the oil that goes into the rotor in a given
revolution be ejected later in that same revolution. Too much oil staying in
place will overheat the oil, cause oil degradation, and reduce heat transfer
from the rotor. I don't know the optimum size in a Mazda.

Jon Lauter, President
Rotary Power Marine Corporation


The Aircraft Rotary Engine Newsletter.              Powered by Linux.

http://home.earthlink.net/~rotaryeng/            http://www.linux.org