Subject: KISS the PSRU goodbye with a ducted fan?
From: Paul
Date: 5/26/1999, 8:07 AM
To: zz

Richard White Wrote:


Here are some numbers for the GE90 (as used on a
Boeing 777, for  example).  With a fan diameter of 123 inches and a
fan rpm of 2485 producing 105,000 pounds of static thrust at sea
level, the fan blade tip speed is 2485/60 * 123/12 * Pi = 1334 ft/sec
which is about mach 1.2, which as the company advertises, is slower
than other typical high bypass engine's fan stages.



F. Marc de Piolenc wrote:

Are you taking into account the deceleration in the fan's inlet
diffuser? I believe that all current commercial turbofans have 
subsonic compressor staging.

Marc de Piolenc
Mass Flow
http://www89.pair.com/techinfo/MassFlow/massflow.htm


I don't think Richard is. I think it is purely a geometrical
calculation. To say that is the mach number is mis-leading as mach
number is usually thought of in terms of local air flow. As
someone pointed out we don't really know the local airflow.

I did watch a Boeing video on the P & W and they did say the 
blades are "transonic". 

BTW It was an eye opener to see what happens to a three
inch thick containment  belt of kevelar in slow motion  when a 
titanium fan blade lets loose from the fan hub at 2400 RPM. Also
chickens going through the fan in slow motion are also 
interesting :-)

IMHO the only trick thing about those ducts is the perforated
sheet metal that lines the duct ahead of the fan. I suspect
that may be for noise suppression. The blade airfoil profiles
do not appear to be anything special except they are very thin
for the cord.

Perhaps Perry needs to use carbon fiber and sharpen up the
leading edge of his fan out near the tips.

Paul Lamar
 
The Aircraft Rotary Engine Newsletter.              Powered by Linux.

http://home.earthlink.net/~rotaryeng/            http://www.linux.org