Subject: cooling on a 20B-how was the car done?
From: Paul
Date: 6/7/1999, 11:46 AM
To: zz

Bob Darrah wrote:


MAR34807@aol.com wrote:

The 20B I have has 2 thermostats mounted in tandem. One neared the pulleys is
a 97 degree C and has a small hole beneath it. The rear thermostat has a much
larger opening below it and is rated 82 degrees centigrade.
Snip

MAR34807, I have the same problem.  The holes under the thermostats allow the
water to circulate through the block without going through the radiator while
 warming up.  Both thermostats should look identical, so that when they
 open, they both close off the hole under them, thereby forcing all water to go
 through the radiator.

I have a little problem with the meaning of the word tandem, I can visualize the term
 mounted in parallel, better.

I, too, would like to know a good way to lower that housing.

Bob Darrah

This is a picture of an auxiliarly water inlet into the front housing
of Racing Beat's 900 HP turbo three rotor. A Chevy engine racing water
pump
was used to feed this inlet and the stock Mazda three rotor water inlet.
The Chevy V8 water pump has two outlets of course.
There are more pictures on the ACRE NL web site of this set up.

Paul Lamar


The Aircraft Rotary Engine Newsletter.              Powered by Linux.

http://home.earthlink.net/~rotaryeng/            http://www.linux.org

auxwater.jpg