Subject: Batteries & modern alternators.
From: Paul
Date: 9/2/1999, 6:39 PM
To: zz

X-Mozilla-Keys:                                                                                 
Bill Freeman wrote:

Tracy Crook wrote:
         *****SNIP *****

It should also be noted that the Mazda alternator (and most other auto
alternators today) use internal regulators.  After these things are up and
running after engine start, they will operate without the external field
connection.  i.e., there is no way to shut them down.

Tracy
rws@altavista.net
http://www.rotaryaviation.com

Paul,

I am using (~ 800 hrs now) a Nippon Denso 55 amp mini
alternator from a (IIRC) '85 Honda Civic.   I connected the
12v field input to my "ALT" side of Cessna split rocker,
and my idiot light to the normal idiot light lug.   This alt has
an internal regulator, but I *can* turn it off with the engine
running.  This is important, since if you get a runaway
voltage output  you *really* want to be able to turn it off.
This would be a critical test when using an auto alternator.
I would ***NOT*** fly in front of one that I could not shut
down.

Bob Nucholls is a great guy, and I recommend those that
needing electrical guidance get his newsletter.  He also
has a neat way to automatically shutdown your runaway
alternator that I may use if I can ever find the time.

Bill


The Aircraft Rotary Engine Newsletter.              Powered by Linux.

http://home.earthlink.net/~rotaryeng/            http://www.linux.org