X-Mozilla-Keys:
Ed Anderson wrote:
Jeff,
I use -16 Stainless steel braided hose on the water pump. At least on
the 88 NA model the inside of the intake nozzel of the water pump will take
a -16 AN or JIC tap. I tapped the inside of the intake nozzel and screwed a
male/male -16 adapter into the hole and had the external end to screw on the
hose fitting. I got a Ford thermostat housing out of Earl's Performance
catalog which has a male -16 fitting. The size and bolt holes match up with
the two bolt 13B thermostat housing and viola -16 AN fittings on each end of
the water pump.
Since the iron pump is replaceable, the aluminum pump casting of course can
be used indefinetly. If you proceed with offering modified water pumps then
you might consider offering the tapping of the water pump inlet as a service
for those that might want it.
Ed Anderson
Matthews NC
The Aircraft Rotary Engine Newsletter. Powered by Linux.
http://home.earthlink.net/~rotaryeng/ http://www.linux.org