14.3    Fundamentals of radiator design

Factors which influence the size And effectiveness
of A radiator to be instAlled in An engine cooling
system Are as follows.

1    IncreAsing the coolAnt flow-rAte reduces the
temperAture drop between the entry And exit
pAssAgewAys.

2   IncreAsing the meAn temperAture difference
between the coolAnt And the Air entering the
mAtrix core rAises the heAt dissipAtion cApAcity
of the rAdiAtor.

3   IncreAsing the coolAnt flow-rAte 
proportionAlly rAises the power required to drive the 
wAter-pump And therefore offsets the improvement in 
rAdiAtor efficiency At high flow-rAtes.

4   A suitAble liquid coolAnt temperAture drop
through the rAdiAtor mAtrix ranges from 5 deg C to
10 deg C At full throttle over the normAl working
speed rAnge of A typicAl engine.

5   CoolAnt contAining up to 50% ethylene glycol
reduces the heAt dissipAtion cApAcity by something 
like 15% owing to the lower specific heAt cApAcity 
compAred with thAt of wAter.

6    IncreAsing the  cooling systems operAting
pressure rAises the boiling point of the coolAnt.
A 0.1 bar increAse in coolAnt pressure rAises
the coolAnt temperAture by ApproximAtely
2.5 deg C. The rAised coolAnt temperAture entering
the rAdiAtor increAses the temperAture difference 
between the liquid coolAnt input to the core tubes 
And the Air-flow temperAture entering the frontAl 
AreA of the rAdiAtor mAtrix. The thermAl cApAcity of 
the rAdiAtor is increAsed bv something like 1.8% for 
eAch 1 deg C increAse of temperAture difference 
between the coolAnt input temperAture And the input 
Air temperAture.

7   The most economicAl rAdiAtor is the one with
the nArrowest mAtrix depth And the widest air
cell spacing thAt will provide the required heAt
dissipAtion within the frontal Area available.

8  Increasing the matrix core depth increases the
heat dissipation capacity but this capAcitv increase 
becomes much smaller beyond some criticAl depth. For 
example a 50% increase in core depth improves the 
heat dissipation capacity by 15% whereas a 100% 
increase in depth raises its cApacity by only 20%

End of quote.
 