Subject: COZY: Spreadsheet for calc of loads
From: Paul
Date: 12/3/1999, 8:17 PM
To: zz

Paul wrote:

Study this drawing. Ask me some questions.

Paul Lamar



Hi Paul,


Frank Davis wrote:

I believe that the drawing of the Cozy motor mount loads attached to the
referenced message lacks a "given" for finding a solution.  That "given"
could be either one or both diagonal lengths or the vertical position of
their intersection at the motor mount.

Cheers, Frank

You are absolutely right Frank. The vertical dimensions are missing for
the 
position of the rubber bushings. 

Not needed in a scale CAD drawing however to calculate the loads. 

Never-the-less you get an A+. Good work. I will have to fix that
drawing.

Paul Lamar
 
The Aircraft Rotary Engine Newsletter.              Powered by Linux.

http://home.earthlink.net/~rotaryeng/            http://www.linux.org

cozyload.gif