Paul Lamar Wrote:
It is hard for me to make that leap to the electrical analogy Bill.
I remember when analog computers were the "hot item", you used voltages and
currents to solve differential equations, so the electrical analogy is
exactly how you would set it up on an analog computer.
Just as current will flow through two parallel paths, so will fluids. the
rates will be different because of the head difference.
OK I think I see your point. And that is; not all return fuel will
go to left tank. Sounds possible.
Right!! The flow will divide in some ratio.
If you really want a "no valve" system, you could make it an electrically
switched "Bonanza look-alike", by just having the return go only to the left
tank. Operation would be:
1. Start on left tank and burn some down.
2. Throw the switch to draw from the right tank and it returns to the left
tank
3. Remember to go back to the left tank in time not to overflow
--repeat
Sounds like a pain. I am spoiled flying a C182. I just leave it
on both and ignore the whole situation.
All switching would be by pump on/off, the piping could be external to the
cockpit (though on the KIS I don't know how one would do this, however you
could have continuous lines with no fittings to leak in the cockpit), and no
expensive Andair type valve with 6 fittings. Only problem is keeping up with
when to switch to avoid dumping fuel.
Perhaps the pump for the right tank could be on a timer, when you switch it
on, it automaticall goes back to the left tank after 30 minutes. Oops,
another failure point, and if it failed in the wrong mode, wouldn't let you
use the RHS fuel.
Another option would be a timer that is kicked in when the right tank pump is
activated, and blinks a big red light after 30 minutes, so the Pilot can
intervene if they want to.
I have come to the conclusion that I will have to pay attention to fuel
management in a low wing plane, just as I have to do with the Archer I fly
now.
Hmm -- I like your bucket test idea, if this hasn't been done by the time I
get to that stage of construction, I just may do it. Right now I need to
keep cutting and bonding fiberglass.
Bill Schertz
I just think we need a really big cross over pipe.
In effect, each pump would draw from both tanks so the pump in the
other tank would be mainly a back up. Almost idiot proof.
I intend to get a flapper valve in the tanks if I can. I am
found of slipping. I like to approach high and slip it in.
Trouble is, the tanks and the wings are already closed on my Cruiser.
There may be flapper valves in there. I need to take another look.
As I recall they may be in the plans.
Paul Lamar