Bill I would not have suggested this but the factor
of safety is quite large. At 30 psi the separating load on a 1.25 ID pipe
joint is about 37 pounds. With a bond strength of 3000 psi and
2.3 square inches to work with we have about a 7000 max load
or a factor of safety of 189 times.
Paul
Dave King wrote:
I'd check for the strength of the bond at temp. Even around 195
it will have degraded quite a bit. Most resins degrade quite rapidly
in strength over 150ish and the drop is a lot steeper than you think.
I'm not talking about the tg temp just the strength. The highest
temp rating for resins I have seen specs on is 350°.
Dave
Even if it drops from 3000 psi to 100 psi it is still way more than
we need with a 1/2 inch overlap on a 1.5 inch OD pipe.
Paul Lamar