marc mularz wrote:
Dave et al:
I think that increasing the % of water from a normal 50/50 ratio would
increase the ability of the coolant to carry heat away from the engine
block. OTOH, I don't believe that this is going to have an appreciable
effect on overall cooling. The cooling is going to be governed by the delta
T of the air/radiator and the volume of air flowing through the radiator.
The mass of additional water in the cooling system (vs. the glycol that it
replaced) is insignificant in the amount of extra heat that it might be able
to hold. Since changing the ratio would be unlikely to change delta T, I
really don't think changing the ratio would have much effect. Furthermore,
as your ratio decreases, the boiling of the coolant becomes a much greater
concern. I think that optimizing the cooling through the radiator is going
to be the key to solving cooling problems.
Right on Marc! The systems that are cooling the best have the best ducts
and intake positions. I whole heartily agree 1000%. Also I might add
the smallest volume of radiators.
Paul Lamar
The other issue is the corrosion in the cooling system. I belive that most
corrosion is a reaction of dissolved oxygen in the coolant with the metal,
and while reducing dissolved ions by using distilled water would help, the
anti-corrosive properties of anti-freeze are very important. There is
probably some minimum ratio to which the anti-freeze can be added and still
help prevent corrosion but that would require some experimentation. Hey I'm
a Chemistry teacher, maybe I can check that. I'll get back to you on this.
As John Slade once said "This is just my opinion, I could be wrong" (or was
that Dennis Miller?) Oh well, back to work.
Take care, Marc M
The AirCraft Rotary Engine NewsLetter. Powered by Linux.