Subject: Making a motor mount.Firewall fitting.
From: Paul
Date: 1/23/2001, 2:51 PM


Since the angles of four of my 7/8 and 3/4 inch OD tubes attached to
the fire wall are near perpendicular it is impractical to use the
traditional methods of using a tube with a bolt in it. This is an
alternative
I am considering. Four 1/4 inch AN bolts or socket head cap screws
with a similar .063 thick 4130  plate on the back side of the ss/fiberglass
laminated plywood fire wall. A lot of little gussets to weld on.
Should distribute the load better into the relatively soft composite
firewall.

Vance what do you think?

Anybody?

 George Lendich wrote:

I've seen that done somewhere recently but can't remember where, probably in
a magazine
for new aeroplane design and automatically put it into the memory banks for
further possible
research, so I would be interested in a response from an engineering
perspective also.
George (down under)


Thanks George. My reasoning is to keep the 1/4 bolt holes as close
to the tube as possible. If hex head bolts are used don't try to use
a box wrench or socket on the bolt heads. Just end wrenches.
Allen head or internal wrenching bolts may be even better.

Paul Lamar

The AirCraft Rotary Engine NewsLetter.              Powered by Linux.

http://home.earthlink.net/~rotaryeng/            http://www.linux.org