Subject: New Andair EFI valve
From: Paul
Date: 4/18/2001, 10:50 PM


marc wiese wrote:

What positions does it have?
Left, Right, Both, and Off would be ideal. Too much to wish for?
Marc Wiese

Remember - generally you can't have a "Both" for a low-wing pumped
fuel system.  With a properly designed and vented sump, this can work,
but the sump and vent are critical, without them the system is totally
unsafe on "both".  "Both" is great for a high-wing gravity feed system.

Bill

 
The AirCraft Rotary Engine NewsLetter.              Powered by Linux.