Subject: High wing fuel management
From: Paul
Date: 4/25/2001, 5:51 PM

Barnhart wrote:

Had two tech counselors from EAA out looking at my wings and the subject of fuel management came up.  My application is a high wing.  20 b  rotary.

Consensus was that front and rear pick ups should be 1/2 inch.  Return line to right wing is low in tank and centered with a 3/8  hose.

Venting is to be done independently from the see thru site gauge for fuel levels.  Site gauges will have a ball that floats on the top of fuel  so it can be seen when using auto fuel, or rough air.   Can't use the same top fitting for venting and top of site gauge.  Both tanks will vent off 3/8 min. hose and tee into a pipe facing forward at least 3/8.  Try to keep both lengths of hose the same to keep the same amount of pressure to both tanks. (Will probably not burn evenly tho) Caps are non venting. This is not an IFR aircraft.  (Will have the Barny triple redundant nav system.  Hand held gps, sectional, and a set of binoculars...)

Fuel burn is determined by which tank lever is open for fuel to be burned.  Too many hours in old beech musketeers....  Return tank is 40 gallons.  Will keep in mind which tank to use for take off and landings depending on fuel temp (ambient and from return)  and quantity.

One lever to control each large tank for fuel management.  Alot easier than multiple tanks and transfer switches. Something I'm used  to flying with.

Use the right type of proseal.

Barny

Barney, bite the economic bullet and buy that Andair EFI valve and return
fuel to the tank you are draining it from. Some day your mind will be distracted.

Paul Lamar

 