Subject: New Andair EFI valve and 'Both'
From: Paul
Date: 4/25/2001, 1:40 PM


marc wiese wrote:

Well, I don't know about all the designs that might be (im)possible and
dangerous to boot, but I envision the use of a "both" setting
returning the
fuel to the 2 belly sumps that drain each left and right tank
individually
a la the C177RG or C210 (in their latest and best iterations) on
HIGH wing
aircraft. These 2 sumps are used for water sump drains collection,
and for
venting purposes. Although elaborate, it seems like it could be made to
work, even if the sumps had to be enlarged for fuel flow return
rates and
temp rise.
Marc Wiese


I would not do that if you are adapting that design to a low wing.

Paul Lamar


Marc,

Is this the system where they increased the fuel line sizes to
something like 3/4" to permit vapor flow 'upstream' back to
the mains from the sump?  I have read that this was the
fix on late 210s to solve a random 'burp' of the engine,
apparently due to vapor buildup in the header trying to
counterflow uphill and momentarily blocking the fuel flow
downhill.   They found this with extensive mockups with
transparent fuel lines.

Bill
Long EZ builder & pilot
BSME, MSME

marc wiese wrote:

I don't know what the fix was for the late model 210 burps but essentially
both model planes have the same configuration (same wings!). Both were
gravity fed, and the backflow depended on hp and model of injection system.
The C177 200hp did not have the 210 problems but still a crossvent
inter-tank connection was added later. The vents are run from each of the
sumps to the tops of each of the tanks, yes, with other venting connections
along the way. Very complicated and wierd.


The AirCraft Rotary Engine NewsLetter.              Powered by Linux.

http://home.earthlink.net/~rotaryeng/            http://www.linux.org