Subject: Air guides in ducts
From: ACRE NL
Date: 5/16/2001, 12:03 PM


"Bass, Jerry" wrote:

Thanks, if I modify the duct as you suggest, will the air move forward,
towards the front of the cooler?  Some who have looked at it say the air
only goes toward the rear.  I have enlarged the air inlet from 2 sq. in. to
8 sq. in.  and blocked the bypass to not bypass with no improvement

Jerry Bass


That's why you need to skinny the back of the duct down a bit.
A straight wedge shape works fairly well but not as well as duct
that is thinned down near the back. Get one of those digital wind
meters and pump some air into the duct with a furnace blower.
Use the wind meter to survey the air velocity coming out of the
back side of the oil cooler. Here is my test set up for radiators.

Paul Lamar

Ken Powell wrote:

_________________________________________________________________
I'm not sure that I remember the original post.  If Jerry is only
using an 8 sq in opening for his oil cooler then the oil probably will
not cool properly.  We all seem to agree that the oil will accept 1/3
of the head of the rotary - Fred Morino recommends a total radiator
inlet size for both the coolant and the oil to be between 66 and
81 sq in.  Based on Fred's estimates we need an oil cooler opening
of at least 22 sq in.  I think we might get away with less because
the Delta T of the oil will be higher since the oil temp is higher than
the coolant temp.  Every time I read Fred's research paper I seem to
learn something new.  This is my best guess based on Fred's research.

Ken Powell