> > >I got it this time Jerry. Some essential suggested changes in red.
> >50 square inches is not enough. Particularly if you are going
> >to tap off induction air. More like 100 square inches is
> >called for. A duct 5 by 19 would be more like it.
> >I am sorry but you cannot get a quart in a pint pot.
> >
> >On the other hand if you flew your airplane upside down
> >on the back of a pickup truck and you proved to me
> >you had at least 20 pounds per square foot or .144 PSI
> >or two inches of water on the face of a rad
> >at 100 MPH I would sign off on a smaller duct :-)
> >
> >Paul Lamar
Jerry Hey wrote:
>
> I think the formula you are using is flawed simply because every
> flying example I have seen is using far smaller inlets. This
> includes all the RVs at Sun-N-Fun if they are using the stock cowls.
> I don't know what Chuck's inlet size is but in the pic I saw it
> seemed much smaller than what you are prescribing.
>
> How do you explain Tracy's, Finn's Ed's and Chucks cooling success?
> If I am wrong about these airplanes, explain to me where I am wrong.
> Chuck Dunlop's rad is, I think, 540 cu in. One forth of that is 135
> sq in. There is no way, he can fit that much intake on his cowl and
> still have something that looks good and flies cleanly. If we
> really have to achieve the inlet sizes you recommend , then the water
> cooled engine is never going to work out for small, light aircraft
> because they simply don't have the space for adequate inlets and even
> larger outlets. I am sure most of the guys on this list want their
> final projects to look every bit as good as the conventional powered
> airplanes on the Ramp. I know this is important to me. Too much
> labor, energy, time and money to settle for an ugly duckling.
>
> However, my impression is just the opposite. Slick airplanes with
> rotarys purring under the cowls are already in the air. On these
> airplanes the average intakes seem to be less that 50 sq. in. (42 Sq
> in for the RVs) I think we should figure out how they are doing it
> and make intelligent use of the information to move ahead. Huge
> inlets seem to be a step backwards.
>
> If my inlets are as large as Tracy's and I provide good ducting and
> adequate outlet, then I expect to have no cooling problems.
> Granted, my submerged inlet proposal needs to be proven, but a 50 sq
> in inlet on the nose of the cowl, perpendicular to the air stream, in
> the prop wash, has already been shown to work.
>
> Shoot me down with real life examples, Jerry
>
> Jerry
Are they successful? Tracy Crook will tell you he does not climb
out at max angle. Also Tracy does not use the stock RV openings.
Chuck will tell you the same thing when the temp gets
over 90 degrees F and he thinks he is still down on power.
Until someone climbs at at max angle on a 100 degree day
with 185 HP or more I will stick by my formula.
I will also modify the formula when I receive info from
the guys indicating their cowl pressure is near zero
relative to static pressure and their airplanes meet
the above criteria.
In addition they are not feeding air through a six foot long duct.
I am just trying to save you a bunch of heartache Jerry.
What are you going to do if your 50 square inch duct does not
cool?
Paul Lamar
Hi Jerry
My radiator is 10 x 20 inches or 200 sq. in. area. 540 cu. in. is the
volume. One fourth of the area would be 50 sq.in. inlet area. My old duct
was down to about 30 sq. in. and still working. I would call it successful
so far but I think it can still be improved. I would not try to climb at max
angle for any extended amount of time in any airplane on a 100 degree day,
and normally would not need to. I just accept that as a limitation and I can
live with it. The inlet and duct shape does make a huge difference whether
> it will work or not. I am sure it will take more than 30 sq. in. to push
enough air through a six foot duct. 50 sq in might be enough, but don't be
discouraged if you have to redo it three times or more like most of us have
had to.
Chuck Dunlap
Thanks for the input Chuck. I have admired your Mazda installation
for a long time. I am not committed to the six foot duct but I am
sure it can be made to work. In some ways it is simpler than my
other option which is two submerged inlets in the belly. Either way
the Rad will be in the same place so I am going ahead with its
installation. As far as having to redo, modify, the installation,
that will not bother me as long as success is eventually likely. Even
air cooled home builts require a lot of tinkering to get it just
right. Pioneers have to expect an occasional arrow through the
heart. Jerry