Marine switches exist for this purpose. Two contact sets are in the housing.
One set feeds current from the normal ignition circuit to the fuel pump. This
contact is closed only when the oil pressure is above a certain threshold (7
psi IIRC). The second contact set provides a means to energize the fuel pump
during cranking by feeding current from the starter solenoid. This contact
set is opened when oil pressure reaches the threshold. Opening this contact
prevents the fuel pump circuit from energizing the starter motor. These are
cheap switches (in both senses of the word), and I have seen a few failures.
Not recommended for aviation IMHO. Perhaps a similar arrangement could be
wired with more robust switches.
Jon Lauter
Rotary Power Marine Corporation
The AirCraft Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://home.earthlink.net/~rotaryeng/ http://www.linux.org