Subject: emergency fuel pump shut-off
From: ACRE NL
Date: 7/22/2001, 8:17 PM


, BUT - if you connect the switch such that a lack of oil pressure
will defeat the fuel pump, are you setting up a situation where if the
engine stalls for some reason, you will have no fuel to re-start??

Al.

Robert Darrah wrote:

You will have to have a by-pass switch to start the engine in the first
place,
same switch for restart.  But there must be other ways to shut off the
pump,
someone must have a better idea.  Let's hear it!

Bob Darrah

"James T. Phillips" wrote:

An inertia switch comes to mind but what if you botch a landing, hit hard
and want to go around with no fuel pressure? I think I would just leave a
switch or breaker and make it an emergency checklist item. I understand that
if you were disabled you would not be able to turn it off. But I think the
risk of it getting turned off and causing or contributing to an accident is
greater. James


 
The AirCraft Rotary Engine NewsLetter.              Powered by Linux.
ACRE NL web site.
http://home.earthlink.net/~rotaryeng/            http://www.linux.org