Rob Weinstock wrote:
Excellent post, Lynn
Shut it off. What to do? Well, you can open the hose and let the air
out. You can run a swirl pot as is done in industry. Rollairtrols they
are
called.( I used to build heat transfer packages). You can put an air
bleed in
Where can I buy these?
You can have fill ports at handy locations around the system. The
fill port(s) are just caps, no pressure relief's. The high spots are
all run
to the bottom of a pressurized bottle, that has the 16 or 22 pound Stant
lever cap on it. The bottom of the recovery bottle is plumbed to the
outlet
of the pressure bottle. The pressure bottle is kept 1/3 full of coolant.
As
the engine heats up and coolant volume increases, the excess coolant and
air
from the high spots moves to the bottom of the pressure bottle. The air
pops
to the top of the bottle. When the coolant changes volume (cools) only
liquid
coolant can be recovered from the bottle. This is not the cooling and
volume
change that occurs on shut down. It is the normal change associated with
power changes. These pressurized make up bottles were used on early
(that I
know of) RX-2s and RX-3s. Toyota also used them. They work great. It
takes
several sessions on the track to get all of the air out of the race
engine.
Can somebody post the schematic for one of these engines' cooling systems?
It is very hard to do. Not doing it will be very$$$$$. If you run a
thermostat, drill a couple of 1/8" holes along the upper edge of the
flange.
Or cut a "V" notch out of it. Otherwise it will not let the air out of
the
engine. The air trapped under the thermostat will not let coolant heat
the
thermostat so it will open. Believe me now for free, or believe me later
for
Great tip!
Thanks and regards,
Rob Weinstock
The AirCraft Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://home.earthlink.net/~rotaryeng/ http://www.linux.org