| Subject: Titanium |
| From: ACRE NL |
| Date: 12/3/2001, 9:36 PM |
Rick Girard wrote:
Never use anything with lead in it on Titanium, or for that matter anything cadmium plated they will both migrate into the Ti lattice and cause cracks. Rick Girard