Al Gietzen wrote:
This cooler goes into the wing root on my Velocity. A photo of the
cavity
is attached. Air intake is at the bottom just behind the spar; exit
faring
on the top. This gets finished out with a layer of fiberglass; the
cooler
slides in and is spaced off the glass with pads of KoolMat. An aluminum
plate supports the inside end and closes off the space.
Al
I really think you are going to have big problems with this installation
Al. I think the pressure will build up enough in front of the cooler
to divert the flow and thicken the boundary layer. We shall see.
Perhaps with a big enough inlet or outlet flap 18 inches long... but that
will disturb a lot of air downstream under or over the wing.
Paul Lamar
It's a tested idea. Other velocity builders have put their standard
aircraft coolers, that have higher pressure drops than mine, in this
configuration; and have had excellent results with NO scoop at the inlet.
When you need the most air flow (climbing) there is significant pressure
difference between bottom and top of the wing. That's a good driving
force - don't know how much; but if it is more than the drop across the
core, it takes surprisingly little negative pressure to encourage the air to
go into the inlet.
I do have a scoop at the bottom, but it is minimal for low drag. Based on
the current evidence, I'm optimistic. And it is a low drag situation using
the pressure difference between the wing surfaces rather than the dynamic
pressure of a scoop.
But you're right - we shall see.
Al
Wing area 122 square foot and you were climbing out
at 100 MPH. Gross weight 2700 pounds 18 pounds per square foot average.
CL roughly is 0.70. Assuming the slot is at an average pressure
point. 0.125 psi.... 3.4 inches of water..... well perhaps.
Interesting thing about this configuration is the pressure
difference across the wing appears to be constant with speed.
It also appears to be a function of the gross weight at
a given speed. Lower weight less cooling. Interesting.
A conventional scoop would have this going for it;
Dynamic pressure is 26 pounds per square foot at 100 mph
or .18 psi or 4.86 inches of water but it gets much much better
at higher speeds. At a climb speed of 120 mph 37 pounds per square foot
.26 psi or 7 inches of water.
Paul Lamar