| Subject: oil pump ratios |
| From: ACRE NL |
| Date: 3/15/2002, 8:11 AM |
Ken Welter wrote:
The 12a has a 31-23 tooth count for a ratio of 1.35 and the 13b has a 36-24 for a ratio of 1.5 does anyone have any experience or thoughts on using the early sprockets on the late pump to get a higher volume. --
The AirCraft Rotary Engine NewsLetter. Powered by Linux. ACRE NL web site. http://home.earthlink.net/~rotaryeng/ http://www.linux.org