Subject: Lead and the O2 sensor was Re: calculating the BSFC
From: ACRE NL
Date: 8/6/2002, 5:44 PM


....l... > >
And Paul is absolutely correct in that O2 sensors usually die quickly if
they see ANY lead.

Also keep in mind that 100LL (Low Lead) has a VERY high lead content.
The
LL description is a hold over from when it was compared to 110 octane
and
other aviation fuels seldom seen any more.

Steve Webre
Broussard, LA

Steve,

I have flown with my O2 sensor installed for 80 hours now using nothing but
100LL and it is still working fine with  my Air/Fuel Ratio indicator meter.
I have read that Lead apparently does adversly affect the sensor's response
time - making it essentially useless for the normal automobile application
where the computer polls its output in terms of 10s of milliseconds or so to
maintain the 14.7 A/F ratio.

But, for use as an indication of oxygen level (and therefore mixture ratio),
80 hours of 100LL does not seem to have had any noticable effect (if its
response time has slowed to 100s of milliseconds rather than 10s - it still
plenty fast for human perception).  I do have one of the slightly more
expensive self heated sensors, so don't know if that may account for its
longer life.  But, saying that even a few second of lead gas kills the
sensor does not apply (at least for the Air/Fuel Ratio indicator usage).

Best Regards

Ed Anderson

 
The AirCraft Rotary Engine NewsLetter.              Powered by Linux.
ACRE NL web site. Copyright 1998-2002 All world wide rights reserved.
http://home.earthlink.net/~rotaryeng/            http://www.linux.org