Subject: How not to do the rubber bushing in the firewall trick.
From: ACRE NL
Date: 8/17/2002, 11:09 PM


How not to do the rubber bushing in the firewall trick.
This puts huge local bending loads on the
firewall. Of course the firewall can be beefed
up with large heavy metal bolt brackets but why?
I did not see any however.

If you put the bushings in the firewall instead
the local bending loads on the firewall are
near zero with a lighter weight design. The
tension, compression and shear loads, in the later case,
are distributed into the composite firewall in
a highly favorable manner. Far superior in fact
to merely bolting the metal motor mount to the firewall.

 Also it makes no sense to have four lower
mounts for a total of six! The one thing he did right
hopefully is tie the lower firewall mounts back to the
landing gear (I hope.)

It totally escapes me why this was done this way.
Perhaps he did not know about Barry mounts and all he
had were Lycoming rubber bushings.

Still???? Sheeesss! The owner was not around.

Oh well too late now. Hopefully it won't fall off.

Paul Lamar


Paul, just to understand well your message. Are you referring to the cups of
the mount being in direct contact with the firewall? Souldn't these cups be
the other way? i.e. the bushing pressed between the firewall and the cup.

Thanks for enlightening,

Alfonso Lebron-Berges

The cups are not in direct contact with the firewall. If they were there would 
be no vibration isolation at all. Yes the bushings should be in 
the firewall with the steel motor mount taking the local bending 
loads on the bolts. See the gif below.

Most MM designs use the bolts in modest bending and that includes the 
Questair venture type. The 1/2 inch bolt and steel spacer in the 22002 
series can take the modest bending loads no problem. The 5/8 inch 
bolt in the 22003 series is so over kill it is ridicules.

However it takes one strong bracket or motor mount cluster to provide 
these bolts with the support they need to take the local bending 
loads on them. That is why I recommend tubes parallel to the firewall 
on all these kinds of bushing in the firewall type mounts. Here is 
an example of this type of mount done right by Perry Mick in perfect way.

BTW the cup washer that the bolt goes through must be 3/16 or thicker
4130 steel.
 
Paul Lamar
 