Subject: RS232 tri state buffers
From: ACRE NL
Date: 12/1/2002, 9:30 AM


BTW Our project to simultaneously record GPS data and rad air & water
temp data has been delayed a week or two. The GPS turned out to be
a Chatty Kathy hogging RS232 time so we need a way to disconnect it
and reconnect it once every couple of seconds. Turning the
power off & on is not a good idea as it takes the GPS
awhile to recover.

Anybody know of a good quad CMOS analog gate that will work
with RS232 signal levels (+/- 12 Volts) ?

Paul Lamar

The MAX243 is a nice RS232 tranceiver that runs on 5V.
I measured the air temp rise on the oil cooler & right side rad last week.
~ 40 - 45 on the oil cooler & 43 - 48 on the rad. Depending on power setting
& climb or cruise condition.  Much smaller range than I expected but it did
confirm my suspicions that a 10 degree rise would be far lower than optimum.
Will be interesting to see how Ed's temps compare.

Tracy Crook
tcrook@rotaryaviation.com
www.rotaryaviation.com

I'll check out the MAX243 Tracy. Thanks.

Paul Lamar

Looks like MAX243's are RS232 voltage levels in/out inverters with TTL in/out.

We need RS232 voltage levels both in & out and buffers.
The data sheet is not clear on the MAX 245. Are those RS232 voltage
levels both in & out? I could use two inverter gates in series to make buffers.

Paul Lamar
 
The AirCraft Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/            
Copyright 1998-2002 All world wide rights reserved.