Russell Kent wrote:
>
> > Thomas Parkes wrote:
> > Question for cooling system engineers. I've set my EIS to warn of
> > coolant temperatures above 220 degrees, but I don't believe I've seen
any
> > data on the actual boiling temperature of 50/50 water/gycol coolant
under 13
> > lbs pressure. What would be a realistic red-line to use?
>
> A 50/50 ethylene glycol (C2H6O2) water blend boils at 223 degF under 1
ATM.
The
> 13 psi working pressure will raise the boiling point another 40 degF (
approx).
> 220 degrees (assuming that's accurate) for 13 psi might be fine, but it
really
> depends on lots of things that are hard to quantify. Where's the
temperature
> reading occuring in the coolant loop? How accurate is the
sender/receiver
system?
>
> Russell Kent
You might try making that a 90/10 glycol mix. Much better heat transffer. And
run a 22 pound cap.
Lynn E. Hanover
The AirCraft Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/