Subject: Tom Parkes Progress & Pressure caps
From: ACRE NL
Date: 2/22/2003, 8:30 AM


Russell Kent wrote:
 >
 > > Thomas Parkes wrote:
 > >     Question for cooling system engineers.  I've set my EIS to
warn of
 > > coolant temperatures above 220 degrees, but I don't believe I've
seen
any
 > > data on the actual boiling temperature of 50/50 water/gycol
coolant
under 13
 > > lbs pressure.  What would be a realistic red-line to use?
 >
 > A 50/50 ethylene glycol (C2H6O2) water blend boils at 223 degF
under 1
ATM.
  The
 > 13 psi working pressure will raise the boiling point another 40
degF (
approx).
 > 220 degrees (assuming that's accurate) for 13 psi might be fine,
but it
really
 > depends on lots of things that are hard to quantify.  Where's the
temperature
 > reading occuring in the coolant loop?  How accurate is the
sender/receiver
system?
 >
 > Russell Kent

You might try making that a 90/10 glycol mix. Much better heat
transffer. And
run a 22 pound cap.

Lynn E. Hanover


On the subject of pressure caps, I've been running a CR Racing cap rated at
30 PSI for the past 3 months.  It gives me an honest 30 psi in the cooling
system (on initial takeoff & climb).  When the temps cool in cruise the
presure drops as expected (typical 15 psi).

After the previous 8 years of using Stant 16 psi caps (gone through at least
4 of them) I now conclude that the Stant caps are junk.  They would hold
13 - 15 psi when new but would quickly drop to 9 - 10 psi max.  I had
previously thought that my old cap fitting was worn out or something.
Problem was the caps all along.  Thanks to Ed Anderson for the tip on CR
Racing caps.

Tracy Crook
tcrook@rotaryaviation.com