Russell Kent wrote:
Dan,
Can you tweak the layout of Perry's situation to look like this and
then re-run the
simulation?
Russell
That outlet duct is a no no Russell. Extensive work has been done on
heat exchanger outlet ducts and all recommend a straight sections before
trying
to turn the flow. Have at it if you wish. No harm in confirming what
has already been done many times before. If the CFD does not show
a problem there is something wrong with the CFD.
Paul Lamar
I'd say there is also a problem with the inlet duct. Converging down
stream from the entrance is likely to cause backpressure which will
spill flow around the scoop.
Al
Yes. I agree Al. Here are the proper coordinates for a perpendicular
heat exchangers for the new members. When you angle the heat exchanger
as Russell has done all bets are off :) It will be interesting
the see what the CFD comes up with.
Paul Lamar