Subject: another pic - perry2 results
From: ACRE NL
Date: 2/26/2003, 8:30 PM


Paul Lamar wrote:

That outlet duct is a no no Russell. Extensive work has been done on
heat exchanger outlet ducts and all recommend a straight sections before trying
to turn the flow. Have at it if you wish. No harm in confirming what
has already been done many times before. If the CFD does not show
a problem there is something wrong with the CFD.


Yeah, I'm aware that pressure wave reflection is an issue with outlets that have no
straight section.  But I'm trying to see if the extreme flow direction change within the
radiator itself is part of the problem.  Thus trying to make the radiator be as close to
perpendicular to the flow as practical (within Perry's limits).  Dan's pressure output
seemed to indicate really high gradiants within the radiator, causing me to wonder if
we're seeing some kind of "micro-scale" wave reflections within the radiator.

Russell Kent


 
The AirCraft Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/            
Copyright 1998-2002 All world wide rights reserved.