> > > > > Hi Yvon;
> > > >
> > > > In Fluid Control systems these are known as "Check Valves" their
purpose
> is to
> > > > hold or prevent the fluid on reverse flow. In other words once the
fluid
> flows
> > > > thru the valve it can not go back through it. So in order
to answer your
> > > > question of whether they are necessary or not a sketch of your fuel
system
> > > > (schematic) is needed.
> > > > Butch
> >
> > I am currently working on my fuel system and the same thing crossed my
mind
> as the positive
> > displacement pumps wont allow to backup through them I don't think they
would
> be needed.
> > I am running two pumps parallel with a pickup in the tank for each pump
and
> the pumps tee
> > together into one line that goes to the carb.
> > Ken Welter
>
********************************************************************************
Hi Ken,......What type of pumps are these, obviously yours are low pressure
since you're feeding a carburetor, how much pressure are they capable of
developing?.....Are they piston, diaphragm, vane, gear?...where
are your check
valves plumbed in.....are they in the two (2) suction
lines?.........Is there
one on the tee'd outlet to the carb?
Butch
I am using Bosch high psi injection pump and a bypass regulator to
cut it down to 4 psi.
I have been running the check valves after the pump before the tee
or to be more specific I am using a Mallory regulator with a multiple
port manifold that I running the lines into.
I cant blow through these pumps so I am going to try it without the valves.
Ken Welter
The AirCraft Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/
Copyright 1998-2002 All world wide rights reserved.