Subject: New water pump -- Testing pumps
From: ACRE
Date: 7/6/2003, 11:43 PM


Anxious to see your results.  All my data, of course INCLUDES the
pressure
drop from going through the engine.

Bill Schertz

I was thinking of simulating the pressure drop in the engine with
a restrictor. Did you get any comparison pressure drop on the engine
verses the pressure drop in the rad? I can also pressurize  the closed
loop system with a shrader valve to see if that has any effect.

Paul Lamar
-----------------------------------
Paul,
Since my water pump was installed on the engine, there was no way to get a
pressure drop reading across the engine block.  I would suggest that you
mill out an adapter plate for where the water pump sits, and plumb the water
to flow through the block. You then can take pressure readings at the inlet
to the pump, the outlet of the pump before the block, and after the block.
this will nail down all the pesky delta-p's and give us real data to work
with.

Also, see if you can borrow a Power meter to get a handle on power as a
function of speed/volume pumped. An ammeter won't cut it, as I found out due
to phase problems.

Good ideas Bill. I will see what I can do. I have a 30 amp breaker on that
2 HP 110 Volt motor as I recall. Should be good to at least 2 HP.

Paul Lamar
 