Subject: Preliminary remote mount water pump plumbing
From: ACRE
Date: 7/17/2003, 7:14 PM


BTW as Don Dunbar pointed out it is real important to keep
the pump inlet as low as possible. On the stock engine
with the high mounted pump a three inch drop in water
level will cause rapid catastrophic overheating as the pump will
suck air. I verified this on the test rig.
Paul Lamar

Paul,
Nice schematic of the pump layout. Have you looked at the stock
accessory drive (the one with the ac & ps pumps on it in that same
location) for a mounting arrangement over there? Seems like it might
work with some mods to it.
[Marc Wiese]

Could be but I will also mount the alternator over there. I need
to work that out in the next few days.

Paul Lamar
 
The AirCraft Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/            
Copyright 1998-2003 All world wide rights reserved.