Keith Moore wrote:
It is time to stop and think about "recycle" of fuel from the engine
to a
header tank (or fuel filter or some other).
1. What happens if air gets in the system?
2. What happens if you run one tank dry, then switch tanks? Where does
the
air go?
I witnessed a completed aircraft rotary engine that would start, run
fine,
then began to sag and quit. Sometimes ran for 5 - 10 minutes. Always
the
same problem.
We put a clear filter in the return line and saw bubbles - with both
pumps
on, some times foam!
The high wing aircraft had two wing tanks, each with a shut off valve.
The
line was Teed to a single line to the engine, typical for all such
designs.
We traced the fuel line from the tank, to the pumps and filters
(parallel
set) to the engine.
But, the fuel return line from the engine went back to the overhead
tanks,
and was "T' to the fuel line from the tank. Any air that got in the
fuel
feed line - would recycle with the fuel, and no where to go to get out
of
the line! The fix was not easy, as the tanks had no "extra" return
fitting.
The same problem will occur with any header system that expects the fuel
suction to keep the header full. These schemes have no way to vent air
from
the header tank. Be assured, air will get in the system some day and
stop
your engine.
The only solution is to return the fuel to the tank from where it came.
That why we all bought the double fuel valve set.
Keith Moore
Long EZ
!
Kieth,
Where was the air coming from ? The first Glastar I tested had the two
vented wing tanks feeding into an unvented header tank. The pumps were
firewall mounted and the return was to the header tank. No problems yet in
almost 300 hours. Could there have been an air leak on the intake side ? If
it would have problems in the first few minutes it wouldn't suggest heating
unless there was a really poor fuel line routing.
John
The AirCraft Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/
Copyright 1998-2003 All world wide rights reserved.