Subject: Recycle Fuel of fuel to filter/header tank
From: ACRE
Date: 8/19/2003, 10:04 AM


Keith Moore wrote:

It is time to stop and think about  "recycle" of  fuel from the engine
to a
header tank (or fuel filter or some other).

1.  What happens if air gets in the system?
2.  What happens if you run one tank dry, then switch tanks?  Where does
the
air go?

I witnessed a completed aircraft rotary engine that would start, run
fine,
then began to sag and quit.  Sometimes ran for 5 - 10 minutes.  Always
the
same problem.

We put a clear filter in the return line and saw bubbles - with both
pumps
on, some times foam!

The high wing aircraft had two wing tanks, each with a shut off valve.
The
line was Teed  to a single line to the engine, typical for all such
designs.

We traced the fuel line from the tank, to the pumps and filters
(parallel
set) to the engine.

But, the fuel return line from the engine went back to the overhead
tanks,
and was "T' to the fuel line from the tank.  Any air that got in the
fuel
feed line - would recycle with the fuel, and no where to go to get out
of
the line!  The fix was not easy, as the tanks had no "extra" return
fitting.

The same problem will occur with any header system that expects the fuel
suction to keep the header full.  These schemes have no way to vent air
from
the header tank.  Be assured, air will get in the system some day and
stop
your engine.

The only solution is to return the fuel to the tank from where it came.
That why we all bought the double fuel valve set.

Keith Moore
Long EZ


Hi, Keith and thanks for the information.  I copied the system that Ed
Anderson has been using quite successfully in his 13b powered RV6. His fuel
goes from the tanks to the header, through the fuel rail/regulator and back
into the header tank.  He has a few hundred hours with this system, so I
copied his. I am in no way an expert on this subject....that's why I copy
what other builders do, once it has proven itself.  For what it's worth.
Paul Conner, 13b powered SQ2000.


Does this system use a separate header tank vent or is it closed?  If the above
problem is a big issue, and getting return lines back to the original tank,
would a header tank vent exiting above the main tank vents allow any trapped air
to escape?  Or could the header tank vent actually pull air preferentially over
fuel if both were possible?

Scott Gettings

 
The AirCraft Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/            