KSE sent me one of these for testing.
It is the same pump that Jim Mederer used on
his 1000 HP three rotor. Unfortunately it has two outputs.
Jim used a freeze plug to add an inlet to the block.
I am thinking of casting a single output housing for this
cartridge. It comes complete with shaft bearings so it
can be belt driven.
Shaft and cartridge are 27 oz. Housing is 23 oz.
KSE claims it puts out 60 GPM at 6000 RPM with a back pressure
of 60 PSI.
Paul Lamar
Paul,
Just use a 180 deg. bend to wrap one output around and gang
them together. I know, easier said than done.
Chris C.
microcosman.com/aircraft
The AirCraft Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/
Copyright 1998-2003 All world wide rights reserved.