Subject: K&N Oil Filters...for acft use
From: ACRE
Date: 2/13/2004, 9:43 AM


The K&N is a 20 micron absolute (not nominal) element, that flows
16 GPM at

70 PSI. This is way more that required for a rotary.

Al Gietzen wrote:

Well; maybe not.  I measured 15 gpm at 6300 rpm (my max operating
poinit) on my 20B.



Al

 