Subject: Mezier electric water pump.
From: ACRE
Date: 11/19/2004, 7:56 PM


A kind person loaned me a Mezier electric water pump to run some
numbers
on. I want to thank you for that.

First thing I noticed was the 20 AMP fuse in the 12 gage motor
wiring. Whoa! Wait a minute! That is a limit of 20 amps times 13 volts
or 260 watts
or .35 HP. As soon as you put some back pressure on this pump either
the impeller will cavitate or the fuse will blow. The stock pump
handles
ten times that amount of HP or around 3.

Then I took it apart and saw the unsophisticated toy impeller and
decided
testing it was a waste of time. A stock Mazda second gen impeller looks
like rocket science along side this toy. I expected a much better
design
based on the questionable advertising claims.

The inlet and out let holes are limited AN -12 or 3/4 inch ID.
No way in hell are you going to get much flow through 3/4 inch holes
both
on the inlet and the outlet. That is .44 square inches and the usual
water plumbing is 1.5 inch or 1.76 square inches or four times more
flow area. No way to increase the size of this plumbing.
In order to test this pump I would need to adapt the 3/4 inch plumbing
to the 1-1/2 plumbing of my water pump test rig. Not worth it!!!

Using this pump in a high powered aircraft engine risks cracking the
rotor housings due to local if not over all overheating.

Paul Lamar


Case closed,   I hope.  How can anyone who has been around the last two
years consider this  pump?    Jerry

Lots of people are betting the farm on this pump?
Bulent

Wow! For the life of me I don't quite understand why I cannot get the physics
principles across on this pump. What am I doing wrong? Why don't people
understand me?

It is ironic that James Watt invented the concept of HP while
pumping water out of a mine. He found that one horse, using a large bucket,
a rope and a pulley could lift 1000 pounds of water 33 feet per minute
out of the mine.

I wrote a basic program today to calculate the absolute minimum amount
of HP required to pump X amount of water against Y pressure.
"Head" and pressure are interchangeable. In other words 30 psi back pressure
is like pumping water to the top of a seven story building. 

Why might you ask is this the case? Well a container one foot square (one cubic
foot) holds enough water to weigh 64 pounds. The bottom of the container
being one foot square is 144 square inches. Therefore each square inch
on the bottom supports .4444 pounds of water. Putting it another way that is
.4444 psi. Since the typical back pressure we have seen on a complete cooling
system can be as high as 30 psi.... 30 psi divided by .4444 is 67.5 feet.

In other words to pump water against a back pressure of 30 psi is the same
as pumping it straight up 67 feet. Now I ask you, do you really think this puny
electric pump can pump 30 gallons of water per minute to the top of a seven
story building from ground level? 

OK 30 gallons of water weighs 240 pounds. We are lifting 240 pound 67 feet
straight up in one minute. Putting it another way that is 16,080 pound feet
per minute. Since James Watt proved that one horse could lift 33,000
pound feet per minute it takes 16,080/33,000 or .487 HP to do the job.
That is the absolute minimum amount of HP to do the job assuming
a 100% efficient pump. No if ands or buts. No getting around it.
It is a FACT. No lie. It is not just a good idea it is the law!

Now, as I pointed out above, an electric motor is about 80% efficient
and a centrifugal pump at best is 70% efficient. The over all
efficiency of the electric water pump is therefore  .7 times .8 or .56 efficient.
You can quibble with these numbers but they are not far off with the
possible exception the mechanical efficiency of the centrifugal water
pump may be much lower than 70%. From the test we have run so far on
the Mazda pump I suspect that is indeed the case.

This mean you are going to have to double the HP number calculated above.

Here is a table of the amount of power it takes to pump X amount of water
against Y pressure. The last number indicates the current required by
an electric water pump to achieve these numbers. The HP number is 
the minimum HP mentioned above and the watts and amps are corrected
for the electric pump efficiency.

If you want to examine the BASIC program let me know and I will upload
the source.

Are there any questions about the calculations? Have I made any errors?

Paul Lamar
 
The Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/            
Copyright 1998-2004 All world wide rights reserved.

  GPH = 15 
      PSI   head ft     HP      Watts    Amps
       4.4      10      0.04      54      4.2
       6.7      15      0.05      81      6.3
       8.9      20      0.07     109      8.3
      11.1      25      0.09     136     10.4
      13.3      30      0.11     163     12.5
      15.5      35      0.13     190     14.6
      17.8      40      0.15     217     16.7
      20.0      45      0.16     244     18.8
      22.2      50      0.18     271     20.9
      24.4      55      0.20     298     23.0
      26.6      60      0.22     326     25.0
      28.9      65      0.24     353     27.1
      31.1      70      0.25     380     29.2
  GPH = 20 
      PSI   head ft     HP      Watts    Amps
       4.4      10      0.05      72      5.6
       6.7      15      0.07     109      8.3
       8.9      20      0.10     145     11.1
      11.1      25      0.12     181     13.9
      13.3      30      0.15     217     16.7
      15.5      35      0.17     253     19.5
      17.8      40      0.19     289     22.3
      20.0      45      0.22     326     25.0
      22.2      50      0.24     362     27.8
      24.4      55      0.27     398     30.6
      26.6      60      0.29     434     33.4
      28.9      65      0.32     470     36.2
      31.1      70      0.34     506     39.0
  GPH = 25 
      PSI   head ft     HP      Watts    Amps
       4.4      10      0.06      90      7.0
       6.7      15      0.09     136     10.4
       8.9      20      0.12     181     13.9
      11.1      25      0.15     226     17.4
      13.3      30      0.18     271     20.9
      15.5      35      0.21     316     24.3
      17.8      40      0.24     362     27.8
      20.0      45      0.27     407     31.3
      22.2      50      0.30     452     34.8
      24.4      55      0.33     497     38.3
      26.6      60      0.36     543     41.7
      28.9      65      0.39     588     45.2
      31.1      70      0.42     633     48.7
  GPH = 30 
      PSI   head ft     HP      Watts    Amps
       4.4      10      0.07     109      8.3
       6.7      15      0.11     163     12.5
       8.9      20      0.15     217     16.7
      11.1      25      0.18     271     20.9
      13.3      30      0.22     326     25.0
      15.5      35      0.25     380     29.2
      17.8      40      0.29     434     33.4
      20.0      45      0.33     488     37.6
      22.2      50      0.36     543     41.7
      24.4      55      0.40     597     45.9
      26.6      60      0.44     651     50.1
      28.9      65      0.47     705     54.3
      31.1      70      0.51     760     58.4
  GPH = 35 
      PSI   head ft     HP      Watts    Amps
       4.4      10      0.08     127      9.7
       6.7      15      0.13     190     14.6
       8.9      20      0.17     253     19.5
      11.1      25      0.21     316     24.3
      13.3      30      0.25     380     29.2
      15.5      35      0.30     443     34.1
      17.8      40      0.34     506     39.0
      20.0      45      0.38     570     43.8
      22.2      50      0.42     633     48.7
      24.4      55      0.47     696     53.6
      26.6      60      0.51     760     58.4
      28.9      65      0.55     823     63.3
      31.1      70      0.59     886     68.2
  GPH = 40 
      PSI   head ft     HP      Watts    Amps
       4.4      10      0.10     145     11.1
       6.7      15      0.15     217     16.7
       8.9      20      0.19     289     22.3
      11.1      25      0.24     362     27.8
      13.3      30      0.29     434     33.4
      15.5      35      0.34     506     39.0
      17.8      40      0.39     579     44.5
      20.0      45      0.44     651     50.1
      22.2      50      0.48     723     55.6
      24.4      55      0.53     796     61.2
      26.6      60      0.58     868     66.8
      28.9      65      0.63     940     72.3
      31.1      70      0.68    1013     77.9
  GPH = 45 
      PSI   head ft     HP      Watts    Amps
       4.4      10      0.11     163     12.5
       6.7      15      0.16     244     18.8
       8.9      20      0.22     326     25.0
      11.1      25      0.27     407     31.3
      13.3      30      0.33     488     37.6
      15.5      35      0.38     570     43.8
      17.8      40      0.44     651     50.1
      20.0      45      0.49     732     56.3
      22.2      50      0.55     814     62.6
      24.4      55      0.60     895     68.9
      26.6      60      0.65     977     75.1
      28.9      65      0.71    1058     81.4
      31.1      70      0.76    1139     87.6
  GPH = 50 
      PSI   head ft     HP      Watts    Amps
       4.4      10      0.12     181     13.9
       6.7      15      0.18     271     20.9
       8.9      20      0.24     362     27.8
      11.1      25      0.30     452     34.8
      13.3      30      0.36     543     41.7
      15.5      35      0.42     633     48.7
      17.8      40      0.48     723     55.6
      20.0      45      0.55     814     62.6
      22.2      50      0.61     904     69.6
      24.4      55      0.67     995     76.5
      26.6      60      0.73    1085     83.5
      28.9      65      0.79    1176     90.4
      31.1      70      0.85    1266     97.4