Subject: Velocity of water through a 1.5 inch ID pipe.
From: ACRE
Date: 11/20/2004, 6:26 AM

Just for the heck of it I thought I would calculate
the velocity of the water going through a 1.5 inch pipe.

The area of the pipe is 1.77 square inches.
A gallon is 235 cubic inches so the length of pipe
needed to hold a gallon is 132 inches long or 11 feet.

At 50 GPM that means water is moving down the pipe at
550 feet per minute or 9 feet per second. 5 MPH.
Not much.  Half the area would be 10 MPH. One quarter
the area or 3/4 inch ID would be 20 MPH. Now we are getting
up there. Inside the valve when the valve was nearly closed
the water would be zinging along however the length of the valve
is minimal so not much friction HP would be lost.

To quote Kays and London again:

"The design of a heat exchanger involves a consideration of both the heat
transfer rates between the fluids and the mechanical pumping power expended
to overcome fluid friction and move the fluids through the heat exchanger.
For a heat exchanger operating with high-density fluids, the friction-power
expenditure is generally small relative to the heat transfer rate, with the
result that the friction-power expenditure is seldom of controlling
influence."

That may be true but it could be partially the cause of the high HP requirements
we are seeing.

"The friction-power expenditure is also increased with flow velocity, but in this
case the power varies by as much as the cube of the velocity and never less
than the square." 

Ah ha!!! So this is why we where blowing circuit breakers on one and two HP motors
and why it took a five HP motor to pump water through the system at 7000 RPM and 
75 gallons a minute. Long passages in the radiator and engine block could
generate considerable HP loses due to friction alone.

 
Paul Lamar
 
The Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://home.earthlink.net/~rotaryeng/            
Copyright 1998-2004 All world wide rights reserved.