Subject: Fuel System Design - w/3 WAY NO Solenoid
From: Rotary Engine
Date: 5/23/2005, 10:39 PM
To: AA-me


Paul;

You have focused on a critical problem; i.e. EFI fuel system with two fuel
tanks .  At some risk to my reputation, may I offer an EFI Fuel System
Design for consideration!

The attached diagram features a 3 way NO (normally open) solenoid valve (5/8
dia).  A switch in the cockpit selects the fuel tank and powers the pump for
that tank.

When the Right tank is selected, the Right pump is ON and the 3-way NO valve
returns fuel to the Right tank.  When the Left tank is selected, the Left
pump is ON and the solenoid valve closes to direct return fuel to the Left
Tank.

Panel LED's show which tank is selected. Fuel Level gages show the tank fuel
levels.  A "flashing / bell" alarm signals a low tank.  A pressure gauge /
alarm reports the status of the fuel feed to the engine.

Note that:
  - Its a simple, fail safe design - intuitive for all  pilots
  - There are no fuel lines in the cockpit!
  - The expensive multiple pipe line selector valve is not required!
  - All active components may be mounted on the fire wall, and/or under the
fuel tanks.
  - There are no surge tanks - all flow is "From - To" the selected fuel
tank
  -  The fuel level in each tank can be easily managed by switching tanks as
required.
   - Dual pump redundancy is maintained - perhaps improved

As further comment,
1.)  Each tank vent line shall first route from the top of the tank to the
bottom of the fuselage and then to the top of the fuselage - so if the plane
flips inverted, gas will not dribble out - don't ask me how I know!

2.) All fuel lines shall include a ground wire to a common point, including
the fuel cap on the tank (particularly for fiber glass tanks).

3.)  Fuel lines in the engine compartment should be stainless steel, and
fire sleeved.  Note the flex lines - as required.

4.) The Long EZ fuel tank has  built in baffles to minimize the movement of
the fuel, such as when in a banked turn.  The design also includes a sump
tank with screen.

5.) Fuel flow rate is computed by summing the EFI injector pulse width.

6.) Observe that the EFI pump flow rate is typically about 10 GPM.  This may
quickly empty a surge tank, even with a large connecting line.    I have
always worried about additional / separate fuel sump tank.

Regards,

Keith (Black Hat) Moore
LEZ


-- 
The Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Copyright 1998-2005 All world wide rights reserved.