Subject: Fuel System Design - w/3 WAY NO Solenoid
From: Rotary Engine
Date: 5/25/2005, 9:07 PM
To: AA-me


 > Paul;

 You have focused on a critical problem; i.e. EFI fuel system with two fuel
 tanks .  At some risk to my reputation, may I offer an EFI Fuel System
 Design for consideration!

 The attached diagram features a 3 way NO (normally open) solenoid valve
 (5/8
 dia).  A switch in the cockpit selects the fuel tank and powers the pump
 for
 that tank.

 When the Right tank is selected, the Right pump is ON and the 3-way NO
 valve
 returns fuel to the Right tank.  When the Left tank is selected, the Left
 pump is ON and the solenoid valve closes to direct return fuel to the Left
 Tank.

 Panel LED's show which tank is selected. Fuel Level gages show the tank
 fuel
 levels.  A "flashing / bell" alarm signals a low tank.  A pressure gauge /
 alarm reports the status of the fuel feed to the engine.

 Note that:
    - Its a simple, fail safe design - intuitive for all  pilots
    - There are no fuel lines in the cockpit!
    - The expensive multiple pipe line selector valve is not required!
    - All active components may be mounted on the fire wall, and/or under
 the
 fuel tanks.
    - There are no surge tanks - all flow is "From - To" the selected fuel
 tank
    -  The fuel level in each tank can be easily managed by switching tanks
 as
 required.
     - Dual pump redundancy is maintained - perhaps improved

 As further comment,
 1.)  Each tank vent line shall first route from the top of the tank to the
 bottom of the fuselage and then to the top of the fuselage - so if the
 plane
 flips inverted, gas will not dribble out - don't ask me how I know!

 2.) All fuel lines shall include a ground wire to a common point,
 including
 the fuel cap on the tank (particularly for fiber glass tanks).

 3.)  Fuel lines in the engine compartment should be stainless steel, and
 fire sleeved.  Note the flex lines - as required.

 4.) The Long EZ fuel tank has  built in baffles to minimize the movement
 of
 the fuel, such as when in a banked turn.  The design also includes a sump
 tank with screen.

 5.) Fuel flow rate is computed by summing the EFI injector pulse width.

 6.) Observe that the EFI pump flow rate is typically about 10 GPM.  This
 may
 quickly empty a surge tank, even with a large connecting line.    I have
 always worried about additional / separate fuel sump tank.

 Regards,

 Keith (Black Hat) Moore
 LEZ

Keith
You have described excactly the fuel system that I had in my RV6A. It worked
perfectly. I will be installing the same system in my new RV7.

Ian Beadle

The Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Copyright 1998-2005 All world wide rights reserved.

Keith and Ian,

Do you have a good source for a NO solenoid valve?  I want install one
in the oil line to my turbo to be used in case of another turbo
failure.  It will prevent loss of the engine oil out the exhaust and
allow continued flight if necessary.

Dave Leonard

 Graingers has them in 24 volt and they will work fine on 12 volts.

 Ken Welter


The Rotary Engine NewsLetter.  Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Copyright 1998-2005 All world wide rights reserved.