Its a real time or sensor resolution problem I think. BSFC and GPH
are jumping around big time.
We have two flow sensors in the system the computer has to read them
both
and subtract the return flow from the forward flow. I would like
the computer to just record both but I don't think that is an option.
We will see what happens this afternoon when we do some power runs.
Paul Lamar
The return flow will be a mix of vapor and liquid. The turbine flow meter
will not read the return flow accurately. It is much better to
recirculate the fuel into a day tank and simply measure the make-up flow
into the day tank. A day tank can be improvised by using the float
system of a carburetor. An alternative is to feed the return flow
through a fuel cooler and then tee it into the fuel pump inlet
downstream of the flow meter. This approach requires careful bleeding of
air from the system and is a little tricky with respect to vapor
re-condensation, small leaks on the low pressure side, etc. The day tank
is "foolproof." It wouldn't hurt to provide some amount of cooling of
the fuel even with the day tank, as the recirculating flow can get quite
hot. I do not believe that you will have any reasonable accuracy using
the two flow meter approach on a recirculating system, but perhaps Dave
has done something different from my own experience. Congratulations on
some FABULOUS work, and here's hoping that you get results that exceed
your goals!
Jon
Thanks Jon Ironically Dave Lemon already has such a set up but Stuska
talked him out of using it I think. If we are still having jitter problems
we may go back to that setup.
BTW your comments on the return flow getting hot is very pertinent
to what we are going through on fuel systems. Got any data on
return flow fuel heat?
Paul Lamar