Paul Lamar wrote:
We [Paul Lamar & Tracy Crook --RAK] discussed how to measure the
pressure wave in the p-port intake manifold as a function of
e-shaft angle during one cycle per revolution of the e-shaft.
The max pressure will occur at different times depending on the
RPM and the length and diameter of the runners. So far suggestions
have been: feeding the output of the high speed pressure sensor
into a PC audio input card or the microphone jack of a note book
computer. Tracy pointed out the problem with that are those are
AC inputs and we need absolute numbers from the pressure sensors.
I'm not certain I completely agree with Tracy's position. It is true
that the EC2 needs to know the absolute pressure in order to determine
the appropriate dwell time for the injectors. But I believe that we are
interested in the shape of the pressure graph in order to learn about
the pressure wave in the intake manifold at various RPMs. In that case,
an AC coupled sensor would work just fine. So for your tests I think
the audio card idea might have been ok, except that I don't know that
the audio card would work very well because of the sampling rate. At
7500 RPM, the e-shaft is generating a 125 Hz TDC signal. If you try to
take a reasonable number of sample in a revolution (like 100) to get a
good idea of the pressure graph, then you're talking 100 * 125 Hz, or
12.5 KHz. And that 100 is really coarse; I'd rather have 200 samples
and that's 25KHz.
We also need to relate them to the ignition pulse. That led to
using a storage oscilloscope instead.
The price of battery powered hand held storage oscilloscope have
dropped recently and they are fast enough to do this job.
At 7500 RPM it takes the e-shaft 8 milliseconds to make one
revolution. In other words that is only 125 revolutions per second.
Since the response times of the pressure sensors is only 1 Kilohertz
most hand low cost held oscilloscopes are fast enough to do this.
Well, you're right, but not for the reasons you think (or at least
expressed). The pressure transducer is a continuous signal output
device. You can sample it at 1 GHz (1,000,000,000 samples / second) if
you're so inclined. But the transducer is only capable of
discriminating a
*pressure* signal of up to 1 KHz. So for example, it
cannot detect most of the notes above upper "C" (C in the octave above
middle C) on an organ as their frequency is over 1 KHz.
But from my math in the earlier paragraph, you only need a sampling
frequency of about 25 KHz to get a good picture of the pressure graph,
which should easily be doable by the most primitive of storage scopes.
They are also fast enough to measure the pulse width of a fuel
injector if you want to use them for that. This device will help
greatly when designing and developing intake manifolds.
Be aware that you'll need either a 2 channel scope or a 1 channel scope
with external trigger in order to relate the recorded signal to some
other event (like TDC). That APS230 looks like the only good candidate.
The PCS500(A) would work, except that it is only an interface to a PC,
not really a standalone scope.
This eBay item might be exactly what you need:
http://cgi.ebay.com/ws/eBayISAPI.dll?ViewItem&item=7530589457
In fact, I may just bid on it. :-)
Russell Kent