Subject: Motor Mount design in gneral.
From: Rotary Engine
Date: 4/24/2006, 8:35 AM
To: AAme

Here is a force diagram and stress calculations
on two motor mount designs.

The size of the arrows are proportional to the loads.
The stress on the lower tube of the first diagram would
not be a problem for 4130 tubing because it is short
and unlikely to buckle. Max allowable stress on 4130 is
66,000 psi. If it were 30 or 40 inches long,
however, buckling would be a severe problem at a
compressive load of 5474 pounds. As shown it is
more a problem for the hard points on the firewall
at 5400 pounds each. Particularly for a composite
or an aluminum firewall. Steel tube fuselages
could deal with it no problem.

The second diagram is what you should strive for.
This illustrates why you should keep the hard points
on the firewall as widely separated as possible.

Paul Lamar ...No rotor no motor.

The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Copyright 1998-2006 All world wide rights reserved.