Subject: Motor Mount design in gneral.
From: Rotary Engine
Date: 4/24/2006, 9:45 PM
To: AAme


Here is a force diagram and stress calculations
on two motor mount designs.





Hi Paul,
I have not been a structural engineer for 40 years, but on checking
your math in the first diagram, I get 2400 lbs tension (21600/9) and
2563 lbs compression (2400 X 25.63 / 24). I think the error is the
dimension between top and bottom pin joint.
Also,  your #2 force diagram has a typo, the vertical distance should
be 15, not 9.  I agree with your #2 math.
BR, Dave McC


Taking moments around the the top tube where it intersects
the firewall I get 24 inches times 900 pounds or 21,600
inch pounds. Since the points are 4 inches top to bottom
apart each force is 21,600 / 4 or 5400 pounds.

There is a vertical (y direction) shear load on the fire wall
of 900 pounds (not shown) as all forces in  a free body diagram
must equal zero. In the  horizontal direction (x) all forces
must also equal zero so the lower 5400 pounds is balanced by
the upper 5400 pounds.

Drawing a scale (one inch equals 100 pounds) right triangle
diagram with the 900 pounds (9 inches) as the vertical leg and
and 5400 pounds (54 inches) as the horizontal leg yields
an hypotenuse length of 54.74" or a load of 5474 pounds in the
diagonal tube in the upper mount.

I did make a slight error in drawing the the second force diagram.
The load is 1695 and not 1686 pounds.

Looks to me like everything else is OK. Both mounts have a 900 pounds
down load.

------------------------------------------------------------------------



Paul,
Your calculations are correct.  The confusion lies in mixing the
physical dimensions that define the geometry with the force vectors that
result from the external loads.  Years ago when I taught EIT and PE exam
review courses, this error  cropped up a lot because of the "get it done
quickly" methods that were espoused in the exam review books.
Aubrey

When I went to school they did not teach this graphical method.
Too hard to measure a pencil drawing. With 2D and 3D CAD programs
it is easy to draw triangles to accurate scale and use
the "aligned dimension" ability to estimate the load. That makes
it more intuitive and quicker than doing the trig.

BTW do you now of any 3D space frame programs that all you need
do is feed it a DXF or iges and it calculates the loads? Does
Solid Works do that? That would be a great thing to have for the
more complicated "bird cage" motor mounts that occasionally show
up. The simple 2D ones are easy to do with the graphical method.
Takes more time to explain it than do it. A 3D version is
not so easy.

Paul Lamar ...No rotor no motor.




Paul,
I know of two programs that are free and appear to be
fairly simple to use.  One is called "Framework" and can
be found here:  http://home.wanadoo.nl/wolsink/

The other is a Java applet that can be found here:
http://engineering.ipfox.com/

Let me see if I can find one of  your old mount pictures
with dimensions and I will test both of these programs to
see how they work.

Aubrey

Good idea Aubrey. I'll see what I can come up with
and add dimensions to an existing design. I suppose
one must enter the dimensions in these programs manually.
In other words they don't take dxf or iges do they?

---------------------------------------

Here are some dims on the Acro Sport mount.


These are perfect.  It's getting late now, but, I'll work on them
tomorrow afternoon.

Aubrey



The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net
Copyright 1998-2006 All world wide rights reserved.