Subject: Renesis coil trouble fix and LS1
From: Rotary Engine
Date: 9/14/2006, 10:59 PM
To: AA-me


Paul,
Here is some information from Tracy on the coil problem.
Ian

Coil/igniters are fairly critical on two things.

(1) Ambient temps around coils should be kept under 130 degrees when run
at constant high rpm operation.  I enclose my coils and have a blast
tube blowing cool air into the enclosure to ensure this.

(2)  Dwell time on coil needs to be correct.  If possible, measure the
running dwell time on the coil (Pin A on RX8 coils, see instructions for
location).  It should be close to 3 milliseconds.  I can't remember the
details of your EC2 order but the Renesis version can be ordered with
one of two options,  LS1 coils (5 millisecond dwell time) and RX-8 coils
(3 MS).  If you have the wrong version the coils could run hot (LS1
running on RX-8 coils) or have weak spark (RX-8 running on LS1 coils).


Ah so. Very good. All makes sense. Jibes with what I measured
on the RX8 car coils. I.E. 2.5 milliseconds. I'll start mounting
coils inside the ram air ducting for the radiators in my 3D's :)
Simple fix.

Have you checked your dwell time yet Ian?

Paul Lamar ...No rotor no motor.

Ian
Aren't the LS1 coils different from the current crop of coils . From what I
can gather the Auto engine management system manage the firing sequence,
spark and duration, where as the LS1 types have some responsibility, which
suggest that there is some solid state management system within the coil
pack itself - as Paul suggests.
Now having absolutely no knowledge of electronics, could this (if all true)
indicate a greater susceptibility to heat. I also wondering if adequate
cooling of the coils is adequate after shut down where there subjected to
heat soak.
George ( down under)

The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site. http://www.rotaryeng.net