Here you go McMaster Carr. $157.
2.2 GPM or 132 gallons an hour at 0 psi.
Way more than enough.
Up to 100 psi. They don't say what RPM
but I suspect it is 1725 RPM which
is what it is with motor.
You will still need a 4 to one reduction.
two inch pulley on the e-shaft and eight inch
pulley on the pump. You might get away with
running it 1/3 as fast 2333 RPM or a 2" to 6"
pulley. You still might need a Facit boost
pump to prime it but the engine should stay
running if the electrical system fails
in flight.
--
Paul Lamar ...No rotor no motor.
Bingo!
Now we have everything we need to put together a mechanical constant
flow FI for a few hundred bucks.
Regards,
Gordon.
Gordon and Paul,
"Not so fast padna." There is a better option and probably just as cheap
er... inexpensive.
May I suggest you use the vane pump that I have 10 years experience running
ozonated water and in the last two years, biodiesel through. On the pump
head there is an adjustment screw to adjust the pressure and it works as an
internal bypass to the inlet side. You adjust the pressure from 0-230 psi.
I think that should be enough:)
I suggest you look at the compact brass pump PDF at:
http://fluid-o-tech.com/
The data is collected at 1725 rpm. I don't know what the upper limit is.
The pumps are originally engineered in Italy but from my experience the guys
in Conn. will answer any questions and help with new applications.
The nice thing about vane pumps is that they both suck and boost well.
The pumps connect to a slotted drive shaft and fasten with a one screw band
clamp only. With a little bit of design effort (ie another bearing and
mount) we could run this pump off of the oil metering pump shaft. Does
anyone know what the ratio between the e-shaft speed and the oiling shaft
output is?
Doug Fir
That is cute :)
My guess is it runs at half speed just like the old
distributors. That is pretty fast for a pump designed to
run at 1725 RPM. Beware of any of these pumps if you
belt drive them. The bearings are not designed for
the side load generated by a belt.
Paul Lamar
Paul,
2:1. Hmmm OK. To go off of the oil pump shaft would need a small $gear box$
and still be rather close to the hot exhaust. Might turn the wrong way as
well. Better to mount that puppy up high somewhere.
Yes you are right about side loads. If run by belt we would need something
analogous to a tube, with a flange on one end, passing perpendicular through
a plate. The single hole on one side of the plate attaches to the engine
block somewhere allowing belt tensioning. Another device is needed to lock
it in place. Something like the alternator uses. The inside of the tube
has a step on each side for a bearing and a U groove on the internal outer
limit of each end for a female spring clip to retain the bearing. The shaft
runs through the middle of the bearings and is locked in one direction by a
step on the shaft and the other side by a male spring clip. One side
contains a key and center bolted 4.5:1 pulley is lightly pressed on. The
pump side is a slotted shaft. The flange on the pump side is where you
attached the unit together. The belt could be tiny for your needs.
WARNING!!!
Carbon graphic pumps do not like sand or to run dry for more than a few
minutes. Don't ask how I know:) Easy to change internal components in
minutes while the unit is attached though. One large (what else) spring
clip, releases the cover plate and internal O ring seal. Slip out the broken
parts and slip in the new ones. Easy. Fast.
Fasten the cowling, crawl back into the cockpit, pull out of the dive,
restart the engine, and resume normal operations:)
Doug Fir
I know you can do a 3D :) How about a 3D on that pump mod?
Paul Lamar ...No rotor no motor.
Paul
Can do. I'll design it so we can use small pulleys as well.
Look at this site and go down the page for the cogged pulley on the BSA
motorcycle.
http://www.srm-engineering.com/parts
With these small size pumps we might be able to design a plate that bolts
to the engine housing and use the oiler shaft with a pulley on it and a 2:1
size pulley on the pump. The fire hazard bothers me though in reality any
where in the cowling that fuel or oil is spraying has the likely hood of
igniting. The whole unit would have to be in an enclosure. The timing
sensor mount might be a better location though I have that place reserved
for a Bendix Magneto.
Doug
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Copyright 1998-2006 All world wide rights reserved.