Paul,
I slapped my forehead when I figured this out.....DUH!
Considering the present cowling shape, I studied a variation of your folded
core cooling block. How about one fold....actually, two radiator cores with
a common tank between them in a vee shape.....intake port at the top and
exit port at the bottom. Scott Gettings keeps going back to this plan, but
the problem was fitting the vertical radiators in a gradually sloping
cowling. Then it hits me...why not give the vee shaped radiators a 90 degree
flip. Now, we've got a ton of room for cooling core because it lends itself
to the cowling shape (see One fold horizontal radiator (Large).jpg). We have
enough room now put more cooling core for water AND oil than we need. With
the rads mounted vertically. it adapts well to wedge diffusers in a
traditional shaped horizontal intake.
I've also included some views of the cowling. Note that there is a lot of
exit air room down both sides of the engine (see Cowling rear (Large).jpg)
In the attached file (One fold horizontal radiator - Thicker Core Numbers
(Large).jpg), there are some numbers for 1.75" and 2" cores.
Q1. What do you think about this plan? What adjustments would you like to
see?
Q2. The 1.5" core offers about what the RX8 has in cooling. Would that be
enough? I sure don't want to overheat in the summer on a Texas taxiway. If
there is any doubt I'd rather have the cooling drag than the heat.
Q3. Can the top intake port and the bottom exit port be on the same side of
a radiator, or is it best to have them on opposite sides?
Thanks for you thoughts
Sandy McNabb
Renesis in a Glass Goose
Looks like it will work fine if you put the tanks on the sides instead
of on the ends. That way top and bottom rad will be in parallel
instead of series.
I talked to the president of Fluiddyne and he was not interested.
I think he was feeling the down turn, He wanted a minimum of 12
cores 12 by 12 by 1 at $300 each. They are worth $100 each at the most.
In other words $3600. He was not familiar with thermo principles.
The engineer if any was not there.
I found a company in Brisbane Aus that understood what we were trying
to do and agreed to make us anything we want including mounting the
tubes at an angle so they are aligned with the air flow. The exchange
rate is good with Aus and George Lendridge lives in Brisbane.
The company is PWR 103 Lahrs Road Orrneau Queensland 4208
The guys name is Matt Bryson 61 7 55547 16111
Email is matthew@pwr.com.au
More on this when I get home.
Paul Lamar
Sandy,
Have you considered a double pass U- style radiator unit? This is really
an efficient use of the delta Ts. in air and water mediums. Mount this
unit where you show the lower V is. Air is ducted straight back (from
the right to left in your picture) and the another exhaust duct delivers
it up and out the top through a cowl flap. This is exactly what I am
doing with my SeaWind set-up but of course yours is a tractor mount. I
need a long duct but you have the advantage of going forward with the
cowling and making a nice inlet shape.
I am concerned you may want all of that area just for the water heat
exchanger. I am also concerned that you are pouring warm air over the
engine, through a fan blade, and other obstruction so that you will
limit the air flow and vastly increase cooling drag. No obstruction on
the inlet and exit is the mantra I have been hearing for about 5 years
now:) And the oil coolers? Put a long 20 B style "2D x 4.5W X23"L
along side the port side bottom quadrant (about 5 o'clock and bring
the air in through an side ear scoop where the cowl is widest. Duct the
exhaust out near the PSRU and the put the prop to work helping to pull
air through the oil cooler as well allowing you to minimize the inlet
size. Adjust the inlet ear in and out to regulate oil temperatures.
Doug in Japan
The Rotary Engine NewsLetter. Powered by Linux.
ACRE NL web site.
http://www.rotaryeng.net
Youtube key word UTUBPLEASE
Copyright 1998-2008 All world wide rights reserved.